We're Here to Help

239.489.0024

Contact Us

info@airscience.com

Vented ENCLOSURE™ for Compounding and Powder Weighing

  • Custom sizes to meet every need. 
  • Turbulent-free airflow pattern. 
  • Proven performance. 
  • Specialized HEPA filter technology for increased safety. 
  • Ductless design increases location possibilities. 
Image 0 Image 1 Image 2 Image 3 Image 4 Image 1

Description

Ideal for containment of powders and fumes during compounding or weighing, Vented ENCLOSURE™ offer important safety features that are not found with any other competitive products.

Model Specifications

Model

arrowDIMENSIONS & WEIGHTS

arrowCONSTRUCTION

arrowPROTECTION & COMPLIANCE

arrowOPTIONS AND ACCESSORIES

arrowAIRFLOW & FILTRATION

arrowELECTRICAL

arrowCONTROLS & MONITORING

Technical Info

External Dimensions
Internal Dimensions
Filter Options
Applications
External Dimensions
Model Width Depth Height
VE-FES-A 17.5" | 445 mm 25.5" | 648 mm 18" | 457 mm
VE-FED-A 35" | 889 mm 25.5" | 648 mm 18" | 457 mm
VE24S-A 24" | 610 mm 28" | 711 mm 19.5" | 495 mm
VE34S-A 34" | 864 mm 28" | 711 mm 19.5" | 495 mm
VE48S-A 48" | 1219 mm 28" | 711 mm 19.5" | 495 mm
VE60S-A 60" | 1524 mm 28" | 711 mm 19.5" | 495 mm
VE34T-A 34" | 864 mm 28" | 711 mm 30" | 762 mm
VE24T-A 24" | 610 mm 28" | 711 mm 30" | 762 mm
VE48T-A 48" | 1219 mm 28" | 711 mm 30" | 762 mm
VE60T-A 60" | 1524 mm 28" | 711 mm 30" | 762 mm
Internal Dimensions
Model Width Depth Height
VE-FES-A - - -
VE-FED-A - - -
VE24S-A - - 17" | 432 mm
VE34S-A - - 17" | 432 mm
VE48S-A - - 17" | 432 mm
VE60S-A - - 17" | 432 mm
VE34T-A - - 28.75" | 730 mm
VE24T-A - - 28.75" | 730 mm
VE48T-A - - 28.75" | 730 mm
VE60T-A - - 28.75" | 730 mm
Filter Options
Formula Description
GP Plus! The most widely used filter in the range, primarily for solvent, organic and alcohol removal.
ACI Plus!/SUL Designed to neutralize volatile inorganic acid vapors.
ACR Iodine and methyl iodide vapors; It is frequently used for iodination reactions with lower level radioactive iodine.
ACM Mercury vapor
AMM Removes vapors from dilute ammonia solutions and to remove low molecular weight amines.
FOR Designed to oxidize formaldehyde and glutaraldehyde fumes; It is widely used in hospital pathology laboratories.
HEPA/ULPA Powders and particulates.
EFT Universal filtration.
SEFA Chemical Compatability Order from Filtco
Applications

Bulk Powder Weighing and Transfers \ Task-Specific Workstations \ Short Duration Projects \ Balance and Microscope Enclosure \ Robotics \ Enclosure \ Compounding Activities

Related Literature

Local Exhaust Ventilation (LEV) Enclosure